The main body shall be surface-treated with zinc-nickel alloy plating; the remaining parts (fittings and end caps) shall, by default, be surface-treated with zinc plating. For special requirements, refer to the technical specifications in the associated drawings. The surface finish shall be uniform in color, smooth and bright, with no obvious plating defects permitted.

Details

Technical Requirements:
Appearance and Anti-corrosion Dispenser
The main body shall be surface-treated with zinc-nickel alloy plating; the remaining parts (fittings and end caps) shall, by default, be surface-galvanized. For special requirements, refer to the technical specifications in the associated drawings. The surface finish shall be uniform in color, smooth and bright, with no visible plating defects such as blistering, porosity, coarse grains, cracking, or localized areas without plating.

The distributor’s coating shall meet the 720-hour neutral salt spray test requirement and comply with the C3 and C4 corrosion protection classes specified in ISO 12944-2.

 

Distribution unit inlet and outlet oil port connection threads
Type DFII

Oil inlet: DIN 24° cone M12×1.5-6; Oil outlet: DIN 24° cone M10×1.0-6
Type DFZ11

Oil inlet: DIN 24° female M14×1.5-6; Oil outlet: DIN 24° male M12×1.5-06
Oil outlet flow rate of the distributor

The oil outlet flow rate complies with the drawing requirements, with a deviation of 10%. The test oil used is VG46# lubricating oil, and the drive pump is an electric lubrication pump.
The distributor’s operating temperature range is -30°C to +60°C; Party B shall provide relevant test certificates.

 

Distributor Pressure Test

Maximum pressure

Under blockage conditions, the distributor pressure is increased to 35 MPa and held for 1 minute; the pressure drop shall be less than 10%.

Start-up pressure

When all ports are functioning normally, the start-up pressure shall be less than 1.5 MPa.
The distributor shall meet a 20-year fatigue service life, and Party B shall provide relevant test certificates.

 